Installation 15
Remote Unit Installation
To install a Remote Unit:
1. Switch off all devices.
2. Connect your keyboard, monitor(s) and mouse to the Remote Unit as shown
in Figure 2.
These ports may also be attached to the CPU side of a KVM switch in order
to have a remote CPU. However, if you are attempting to use the extender
between cascaded KVM switches this may not work. Please contact Technical
Support to discuss your application.
3. If appropriate, connect audio equipment and serial devices. Connect the
audio cables as follows:
Remote Unit Audio Device
Audio Out Speakers
Audio In (MIC) Microphone
See Appendix E: Audio/Serial Ports: Operation & Multi-Port
Configuration, page 45 for further information.
4. Connect the Primary CATx cable to the INTERCONNECT (1) socket on
the front of the Remote Unit. If required, connect the Secondary CATx
cable to the INTERCONNECT (2) socket on the front of the Remote Unit
(see Figure 3).
5. Connect the 9V power supply to power the unit.
Only use the power supply originally supplied with this
equipment or a manufacturer approved replacement.